Restore archived samples from an external device to Ion Reporter™ Server

This information applies only to Ion Reporter™ Server.

If needed, you can restore the analyses that you have archived in Ion Reporter™ Software.

IMPORTANT! Ensure that you restore archived samples only on the Ion Reporter™ Server on which the samples were originally archived.

  • The external storage device that contains archived samples must be mounted to your Ion Reporter™ Server.

  • If you have a new Ion Reporter™ Server or upgrade from a previous version, you must specify a storage location for archiving samples and analyses in Ion Reporter™ Server.

    IMPORTANT! Change archivalMountPath=/tmp/ to archivalMountPath=/storage IP address/ in the ionreportermanager/server/server.properties file, then restart the Tomcat server.

    To check the data that you archived, go to the storage location of the archived data, which is set up in the /share/apps/IR/ionreportermanager/server/server.properties file as archivalMountPath.

    If you have questions about the Tomcat server, contact your Field Support Engineer or Field Bioinformatics Support representative.

  1. In the Samples tab, find the archived sample.

    An archived sample shows  (Archived) in the row of an analysis.

  2. To restore the archived sample back onto the Ion Reporter™ Server, do one of the following:
    • Select the archived sample or samples, then click Actions > Restore.

    • Click  (Restore) to return the sample back to the Ion Reporter™ Server.

The sample or samples are restored.